Please use this identifier to cite or link to this item: https://hdl.handle.net/10923/8211
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorGrossi, Márcio Lima
dc.contributor.authorSilva, Carlos Augusto Gomes da
dc.date.accessioned2016-05-07T12:04:33Z-
dc.date.available2016-05-07T12:04:33Z-
dc.date.issued2016pt_BR
dc.identifier.urihttp://hdl.handle.net/10923/8211-
dc.description.abstractO objetivo do presente estudo foi verificar a possibilidade da criação de um modelo tridimensional do sistema mastigatório de um paciente para análise em MEF. E também, configurar os parâmetros para a realização de um teste de apertamento dentário com variações nas intensidades de força de mordida com a interposição de duas placas oclusais de diferentes materiais. A partir dos exames de tomografia computadorizada (TC) e ressonância magnética (RM) de um paciente foram construídos, por meio de engenharia reversa, sete peças para compor um biomodelo. Quatro softwares foram usados em todo o processo até atingir o resultado desejado. Ainda, a partir deste modelo foi criada a malha de elementos finitos dos componentes e definidas as condições de contorno. Uma placa oclusal foi criada e suas propriedades físicas e mecânicas foram alternadas para simular o comportamento de duas placas distintas: uma rígida e uma resiliente. O modelo recebeu vetores de força que simularam a ação de quatro pares de músculos: temporal, masséter, pterigoideo medial e lateral; e foi atribuído a estes, três forças distintas para cada teste: 25ON, 50oN e 75oN. De acordo com o que foi apurado neste estudo é possível concluir que a construção de um biomodelo a partir de imagens de TC e RM e plenamente viável. Além disso, a metodologia adotada para obtenção dos modelos e as configurações definidas para os testes em MEF resultaram em uma boa aproximação a realidade clinica seguindo a linha das pesquisas vigentes.pt_BR
dc.description.abstractThe aim of this study was to investigate the possibility of creating a three-dimensional model of the masticatory system of a patient for analysis in MEF. Also, to configure the parameters for the attainment of a clenching test with variations in intensities bite force with the interposition of two occlusal splints of different materials. Using the computed tomography (CT) and magnetic resonance imaging (MRI) of a patient, were built, through the process of reverse engineering, seven pieces to compose a biomodel. Four software was used throughout the process to achieve the desired result. Also, from this model was created finite element mesh of components and defined the boundary conditions. An occlusal splint was created and its physical and mechanical properties were switched to simulate the behavior of two different plates: a rigid and resilient. The model received force vectors that simulate the action of four pairs of muscles: temporal, masseter, medial pterygoid and lateral; and was assigned to these three distinct forces for each test: 25oN, 50oN and 75oN. According to what was found in this study it can be concluded that the construction of a biomodel from CT and MR images are completely feasible. In addition, the methodology used to obtain the models and the settings configured for the tests in MEF resulted in a good approach to clinical reality along the lines of current research.en_US
dc.language.isoPortuguêspt_BR
dc.publisherPontifícia Universidade Católica do Rio Grande do Sulpt_BR
dc.rightsopenAccessen_US
dc.subjectPLACAS OCLUSAISpt_BR
dc.subjectPRÓTESE DENTÁRIApt_BR
dc.subjectELEMENTOS FINITOSpt_BR
dc.subjectODONTOLOGIApt_BR
dc.titleConstrução de um biomodelo com interposição de placa oclusal para análise de tensões nos discos articulares da ATM pelo método dos elementos finitospt_BR
dc.typemasterThesispt_BR
dc.degree.grantorPontifícia Universidade Católica do Rio Grande do Sulpt_BR
dc.degree.departmentFaculdade de Odontologiapt_BR
dc.degree.programPrograma de Pós-Graduação em Odontologiapt_BR
dc.degree.levelMestradopt_BR
dc.degree.date2016pt_BR
dc.publisher.placePorto Alegrept_BR
Appears in Collections:Dissertação e Tese

Files in This Item:
File Description SizeFormat 
000478489-Texto+Parcial-0.pdfTexto Parcial131,64 kBAdobe PDFOpen
View


All Items in PUCRS Repository are protected by copyright, with all rights reserved, and are licensed under a Creative Commons Attribution-NonCommercial 4.0 International License. Read more.