Utilize este identificador para citar ou criar um atalho para este documento: https://hdl.handle.net/10923/11940
Registro Completo de Metadados
Campo DCValorIdioma
dc.contributor.advisorTeixeira, Eduardo Rolim-
dc.contributor.authorFulginiti, Roberta Limeira-
dc.date.accessioned2018-07-03T12:03:17Z-
dc.date.available2018-07-03T12:03:17Z-
dc.date.issued2016pt_BR
dc.identifier.urihttp://hdl.handle.net/10923/11940-
dc.description.abstractO objetivo desde estudo foi analisar se os diferentes pontos de fusão de ligas de cobalto-cromo (Co-Cr) para sobrefundição podem influenciar na adaptação marginal de cilindros pré-fabricados para prótese implantossuportada. Duas ligas metálicas de Co-Cr com pontos de fusão distintos indicados pra técnica de sobrefundição foram fundidas aos cilindros pré-fabricados com base de Co-Cr. As amostras foram confeccionadas, fixando os cilindros aos pilares e embutidas em resina epóxi, formando três grupos de acordo com a liga utilizada. Grupo 1: controle (cilindros de fábrica); Grupo 2: liga de Co-Cr com menor ponto de fusão (LMT); Grupo 3: liga de Co-Cr com maior ponto de fusão (HMT). As amostras foram seccionadas longitudinalmente na porção central do conjunto por uma máquina de precisão, polidas e encaminhadas para avaliação por microscopia eletrônica de varredura óptica. As imagens foram analisadas e verificadas a presença de desadaptações. Cada área de desadaptação entre cilindro e pilar foram medidas. Os resultados demonstraram significância (p<0.005) para o grupo em que os cilindros pré-fabricados foram sobrefundidos com a liga de maior ponto de fusão apresentando áreas de desadaptação marginal ao pilar. O grupo HMT demonstrou valores médios para área de 2,489 μm2 (±1,073), o grupo LMT de 1,536 μm2 (± 0,375) e enquanto o grupo controle de 1,272 μm2 (± 0,577). Para as medidas de estabilidade dimensional não foram observadas diferenças estatísticas (p>0.005) entre os grupos experimentais. Contudo, indica-se que para sobrefundição de cilindros pré-fabricados a liga metálica utilizada não deve possuir ponto de fusão acima do preconizado pelo fabricante do cilindro.pt_BR
dc.description.abstractThe purpose of this study was to evaluate the influence of Co-Cr dental casting alloys presenting distinct melting ranges for compound casting technique, with lower and higher melting temperature, on the marginal adaptation of prefabricated cast-to implant cylinders for implant support prosthesis. Two cobalt-chromium base metal alloys were cast to prefabricated Co-Cr cast-to implant cylinders. The cylinders were placed in the abutments and mounted in epoxy resin. Three groups were formed according with base alloy. Group 1: Cylinder as manufactured (Control); Group 2: lower melting temperature alloy; Group 3: higher melting temperature alloy. The specimens were ground to their central portion longitudinally by a surface grinding machine, polished and evaluated by optical and scanning electron microscopy. The images were analyzed and the misfit areas between the cylinders and abutments were, if present, measured. For statistical evaluation of misfit areas ANOVA multivariate analysis and Tukey tests were used. Pre-fabricated cast-to cylinders which received higher melting temperature alloy showed significant differences in terms of marginal misfit. No significant differences were observed comparing the control and the lower melting temperature alloy group. Co-Cr casting alloy with a higher melting temperature cast on prefabricated Co-Cr implant cylinders might induce greater marginal misfit areas. The selected alloy for compound casting must not exceed the melting temperature of prefabricated implant cylinder base as recommended by manufactures.en_US
dc.language.isoPortuguêspt_BR
dc.publisherPontifícia Universidade Católica do Rio Grande do Sulpt_BR
dc.rightsopenAccessen_US
dc.subjectPRÓTESE DENTÁRIApt_BR
dc.subjectLIGAS METÁLICASpt_BR
dc.subjectIMPLANTODONTIApt_BR
dc.subjectODONTOLOGIApt_BR
dc.titleAnálise da adaptação marginal e alteração dimensional de supraestruturas próteticas fundidas em diferentes ligas de Co-Crpt_BR
dc.typemasterThesispt_BR
dc.degree.grantorPontifícia Universidade Católica do Rio Grande do Sulpt_BR
dc.degree.departmentFaculdade de Odontologiapt_BR
dc.degree.programPrograma de Pós-Graduação em Odontologiapt_BR
dc.degree.levelMestradopt_BR
dc.degree.date2016pt_BR
dc.publisher.placePorto Alegrept_BR